Bosch Alarm
bosch_alarm
The Bosch Alarm Panel integration allows you to connect your Bosch Alarm Panel to Home Assistant to control and monitor your Bosch Alarm Panel.
In Apple Home through HomeKit Bridge
What HomeKit Bridge makes of each kind of entity this integration creates, read from its source code. A device only gets the ones that apply to it.
| Entity | Shows up as | Note |
|---|---|---|
switch | Switch or outlet | |
alarm_control_panel | Security system | |
binary_sensor | Sensor (motion, contact, leak, smoke…) |
2 reports below say how a device from this integration behaves in the Home app.
What people report
Bosch Solution, B/G Series, AMAX and D-series panels are supported over the local connection. Older panel firmware can lock up the IP module, and cloud connections can conflict.
- Works7
- Partly works1
| Device | In Home Assistant | In Apple Home | What they said | Source |
|---|---|---|---|---|
| Bosch AMAX 2100/3000/4000 | Works Local | Listed as supported; panel config must be done in Bosch utilitySaved copySupported devices: Solution 2000/3000/4000; B Series: B3512/B4512/B5512/B6512; G Series: B8512G/B9512G; AMAX 2100/3000/4000; D7412GV4/D9412GV4 [^1]. Limitations: The integration does not allow you to configure the panel; you can instead do this via the panel's configuration utility. Some older firmware versions for the Solution / AMAX series panels only support a single connection at a time. If you try to have a cloud connection and use the integration on these panels simultaneously, the panel's network stack can lock up, and the integration will stop working. Excerpt saved from home-assistant.io on 2026-10-23. | Docs | |
| Bosch B3512/B4512/B5512/B6512 | Works Local | Listed as supported; panel config must be done in Bosch utilitySaved copySupported devices: Solution 2000/3000/4000; B Series: B3512/B4512/B5512/B6512; G Series: B8512G/B9512G; AMAX 2100/3000/4000; D7412GV4/D9412GV4 [^1]. Limitations: The integration does not allow you to configure the panel; you can instead do this via the panel's configuration utility. Some older firmware versions for the Solution / AMAX series panels only support a single connection at a time. If you try to have a cloud connection and use the integration on these panels simultaneously, the panel's network stack can lock up, and the integration will stop working. Excerpt saved from home-assistant.io on 2026-10-23. | Docs | |
| Bosch B8512G/B9512G | Works Local | Listed as supported; panel config must be done in Bosch utilitySaved copySupported devices: Solution 2000/3000/4000; B Series: B3512/B4512/B5512/B6512; G Series: B8512G/B9512G; AMAX 2100/3000/4000; D7412GV4/D9412GV4 [^1]. Limitations: The integration does not allow you to configure the panel; you can instead do this via the panel's configuration utility. Some older firmware versions for the Solution / AMAX series panels only support a single connection at a time. If you try to have a cloud connection and use the integration on these panels simultaneously, the panel's network stack can lock up, and the integration will stop working. Excerpt saved from home-assistant.io on 2026-10-23. | Docs | |
| Bosch D7412GV4/D9412GV4 | Works Local | Listed as supported; panel config must be done in Bosch utilitySaved copySupported devices: Solution 2000/3000/4000; B Series: B3512/B4512/B5512/B6512; G Series: B8512G/B9512G; AMAX 2100/3000/4000; D7412GV4/D9412GV4 [^1]. Limitations: The integration does not allow you to configure the panel; you can instead do this via the panel's configuration utility. Some older firmware versions for the Solution / AMAX series panels only support a single connection at a time. If you try to have a cloud connection and use the integration on these panels simultaneously, the panel's network stack can lock up, and the integration will stop working. Excerpt saved from home-assistant.io on 2026-10-23. | Docs | |
| Bosch Solution 2000/3000/4000 | Works Local | Listed as supported; panel config must be done in Bosch utilitySaved copySupported devices: Solution 2000/3000/4000; B Series: B3512/B4512/B5512/B6512; G Series: B8512G/B9512G; AMAX 2100/3000/4000; D7412GV4/D9412GV4 [^1]. Limitations: The integration does not allow you to configure the panel; you can instead do this via the panel's configuration utility. Some older firmware versions for the Solution / AMAX series panels only support a single connection at a time. If you try to have a cloud connection and use the integration on these panels simultaneously, the panel's network stack can lock up, and the integration will stop working. Excerpt saved from home-assistant.io on 2026-10-23. | Docs | |
| Bosch Solution 3000 | Works Local | Partly in Home Arming from Home app via HomeKit Bridge left area stuck arming | Fixed after report: area went unavailable after arm/disarmSaved copy… connecting to the panel seems to allow home assistant to update status. User code is correct despite what the logs stating "No authority". B426-M 3.15.214 Solution 3000 2.1.3 If you need any more info, let me know. Thanks! ### What version of Home Assistant Core has the issue? 2026.1.3 ### What was the last working version of Home Assistant Core? 2026.1.2 ### What type of installation are you running? Home Assistant OS ### Integration causing the issue Bosch Alarm ### Link to integration documentation on our website https://www.home-assistant.io/integrations/bosch_alarm/ ### Diagnostics … Excerpt saved from GitHub on 2026-10-23. | Issue #161606 · 2026-01 |
| Bosch Solution 3000 alarm panel | Works Local | Partly in Home Arming from Home app via bridge left area unavailable | Fixed after report; arm/disarm made area unavailableSaved copyThe problem Arming/disarming via Home Assistant or Homekit (via Homekit Bridge) leads to "AREA1 became unavailable". Both the panel and IP firmware are fully up to date. Was working fine on 2026.1.2. Arming via Home Assistant does work (confirmed by beep from keypad) but the status does not update and remains stuck on "arming". Then AREA1 and all sensors become unavailable. RSC+ app sends notification that the alarm is armed. For some reason, opening the RSC+ app and connecting to the panel seems to allow home assistant to update status. User code is correct despite what the logs stating "No … Excerpt saved from GitHub on 2026-10-23. | Issue #161606 · 2026-01 |
| Bosch Solution 2000 IP module | Partly works Local | IP module locks up periodically; panel/IP firmware updates advisedSaved copyThe problem Was great when the Bosch Security integration first came online, able to control a Solution 2000 and related relays, too. Unfortunately every now and then the connection dies - which I'm fairly sure is the IP module locking up on the alarm side. The alarm (eventually) resets the IP module, as I see a touchpad message of "IP Module #1 Fault" and it emits a low tone, after which the connection comes back online. There's nothing I do (that I'm aware of) that immediately causes the IP module to fail. It can run for a few hours or a few days, then fails / (integration unable to reach … Excerpt saved from GitHub on 2026-10-23. | Issue #155173 · 2025-10 |
Gathered from GitHub issues, pull requests, discussions and docs, and from r/homeassistant. These are individual reports, so check the linked thread and the date before you buy.
How it connects
Local push
Talks to the device on your network, and the device tells Home Assistant the moment something changes.
Found automatically over
- DHCP
Details
| Installs (analytics) | 142 (0.02%) |
|---|---|
| Quality scale | Platinum |
| Added in | Home Assistant 2025.4 |
| Set up in the UI | Yes |
| Maintainers | @mag1024, @sanjay900 |
Devices listed in its documentation
- Solution 2000/3000/4000
- B Series: B3512/B4512/B5512/B6512
- G Series: B8512G/B9512G
- AMAX 2100/3000/4000
- D7412GV4/D9412GV4 [^1]
Limitations from the docs
- The integration does not allow you to configure the panel; you can instead do this via the panel's configuration utility.
- Some older firmware versions for the Solution / AMAX series panels only support a single connection at a time. If you try to have a cloud connection and use the integration on these panels simultaneously, the panel's network stack can lock up, and the integration will stop working.
In ReReHome
Whatever HomeKit Bridge shares reaches Apple Home as normal HomeKit accessories behind your Home Assistant bridge, so ReReHome shows and controls them like any other.
Bridges get their own settings page listing the accessories behind them.